MODEL ITEMS |
DF3300A-220/DF3300A-110 |
ADC220V/ADC110V |
1 |
NOMINAL OUTPUT VOLTAGE |
V |
V1 |
V2 |
V3 |
V4 |
V5 |
5 |
+12 |
-12 |
24 |
24 |
2 |
MAXIMUM OUTPUT CURRENT(CONVECTION) |
A |
1 |
0.15 |
0.15 |
0.5 |
0.2 |
3 |
MAXIMUM OUTPUT POWER (CONVECTION) |
W |
25.4 |
4 |
EFFICIENCY(*1) |
- |
>70% |
5 |
INPUT VOLTAGE RANGE |
- |
DC176~360V/DC88~132V
AC176~264V/AC88~132V |
6 |
INRUSH CURRENT(TYP) |
A |
28 |
7 |
DC OUTPUT VOLTAGE SETTING |
V |
±5% |
|
|
|
|
8 |
OUTPUT VOLTAGE PRECISION (*2) |
- |
±1% |
±3% |
±3% |
±5% |
±5% |
9 |
MAXIMUM LOAD REGULATION(*2) |
- |
±1% |
±3% |
±3% |
±5% |
±5% |
10 |
MAXIMUM LINE REGULATION(*2) |
- |
±1% |
±3% |
±3% |
±5% |
±5% |
11 |
MAXIMUM RIPPLE NOISE(*3) |
mV |
50 |
80 |
80 |
80 |
80 |
12 |
POLARITY |
|
V1,V4,V5 substantive V2,V3 together |
13 |
OVER SHOOT |
V |
10% |
14 |
OVER POWER PROTECTION |
- |
V1,V2,V3 SHUT OFF ALL O/P,V4,V5 SHUT-OFF V4,V5 O/P,OUT OF LOAD FOR 2SEC,RECOVERS AUTOMATICALLY |
15 |
OVP PROTECTION |
- |
V1≥10% |
|
|
|
|
16 |
OUTPUT ALARM |
V |
V1<4.75V AL OUTPUT ALARM SIGNAL |
17 |
START-UP DELAY TIME(*4) |
mS |
V1 THAN V4 80~120 |
18 |
SHUT-OFF DELAY TIME(*4) |
mS |
V4 THAN V1 |
19 |
OPERATING TEMPERATURE |
- |
-10~+55℃ |
20 |
STORAGE TEMPERATURE |
- |
-25~+75℃ |
21 |
WITHSTAND VOLTAGE |
- |
INPUT-FG: 2KVAC 1min. OUTPUT-FG: 2KVAC 1min .INPUT-OUTPUT: 2KVAC 1min.TOUCH-OUTPUT:2KVAC 1min.OUTPUT-OUTPUT:500VAC 1min,( LEAKAGE CURRENT:10mA) |
22 |
STRIKE |
|
LOOP-FG:5KV |
23 |
ISOLATION RESISTANCE |
- |
MORE THAN 300MΩAT 25℃ |
24 |
WEIGHT(TYP) |
Kg |
0.45 |
25 |
SIZE(W*H*D) |
mm |
REFER TO OUTLINE DRAWING |
NOTES:
*1.BEFORE ADC INPUT ,TURN VR FULLY CLOCKWISE
*2. V1,V2 V3 V4 V5 AT 0%~100%LOAD.
*3. 20MHz BANDWIDTH SCOPE.
*4. AT 80%LOAD TO TEST. |